CPHD

Required Residential Inspection

 

 

NOTIFY "MISS UTILITY" AT 1-800-257-7777
48 HOURS PRIOR TO START OF ANY EXCAVATION.

SEQUENCE OF INSPECTIONS FOR RESIDENTIAL SINGLE-FAMILY AND TOWNHOUSE CONSTRUCTION *

For Inspections call 228-3700




INSPECTION TYPE

PERMIT TYPE

WHEN

1) Footing

Building

Before pouring concrete

2) Groundwork

Plumbing

Before backgrading

3) Slab

Building

Before pouring concrete

4) Foundation Walls

Building

Before pouring concrete walls, or for reinforce CMU walls.

5) Backfill

Building

After waterproofing or before backfilling.

6) Rough-in

Plumbing 

Mechanical

Electrical

Before covering work & 1st Gas Test (if applicable)

7) Braced Wall Nailing

Building

Before Building Wrap or windows installed

8) Framing

Building

After trade rough-ins (allows insulation)

9) Insulation

Building

After insulating (allows close-in).

10) Gas Test

Plumbing

Before concealing gas piping.

11) Final

Electrical 

Mechanical

Electrical

After work is complete

12) Final

Building

After trade finals, before Certificate of Occupancy.

Other Inspections: (Timing depends on needs)

Service

Electrical

After upgrading service box

Temporary Power

Electrical

Before Virginia Power will

Concealment Ditch

Electrical

Before backfilling trench

Fireplace

Building

Fireplace hearth or throat inspections.

Sewer/Water Service

Plumbing

When tapping mains/before backfill